ChFN trochanteric nail

ChFN trochanteric nail is intended for intramedullary osteosynthesis of subtrochanter femur fractures.
Implants are made of titanium alloy, thus the scope of the MRI diagnostics is broadened because of the high biocompatibility.
It is possible to enhance the fracture stabilization by application of additional join screw that eliminates rotation of the femur neck (protects the femoral head for the rotation).
All necessary implants are placed on a convenient stand.

ChFN2 trochanteric nail

ChFN2 trochanteric nail
The decreased diameter of the proximal part of the nail reduces the traumatisation of tissues and blood vessels.
Telescopic screws, designed specially for the system, minimize the risk of screw migration in the femoral neck.
The surgeon can decide to open the intramedullary canal with an awl or with a drill that has the same diameter as the proximal part of the nail.
New instrument set is lighter and even more user-friendly.
 
Indications:
  • femur shaft fractures;
  • subtrochanteric and intratrochanteric fractures;
  • femur neck fracture;
  • pathological fractures;
  • pseudarthrosis;
  • malunion and non-union treated with other methods.

7.0ChLP femoral shaft plates

INDICATIONS:

  • comminuted fractures of femur shaft;
  • malunion or non-union of the bone.

Due to the more favorable force distribution, it is recomeded to use longer plates.

It is not allowed to profile the locking plates in percutaneous method of implantation with the use of targeters. Implant profiling prevents its proper functioning with the targeter.

elastic nails for children

CHARFIX femoral nail

CHARFIX femoral nail is a universal solution, which depending on a fracture type, enables the intramedullary fixation with the reconstructive, compression, dynamic, static or retrograde method.
Retrograde nail insertion grants the intramedullary osteosynthesis of a femur, in which there already has been a hip prosthesis or other implant inserted in its proximal part.
The locking set – an integral part of the system allows the compression fixation of the condyles.
The combination of three different nails in one implant improves effectiveness of the whole medical team – simplifies mastering of the surgery technique, reduces logistic problems and gives a great flexibility during the surgery.

CHARFIX2 anatomical femoral nail

CHARFIX2 anatomical femoral nail is a next generation nail that is shaped in several planes to better match the femur anatomy. The nail can be inserted through the lateral insertion point.
This makes the implantation easier and results with less trauma to the patient.
The nail enables to fix femur applying static, dynamic, compression or reconstructive intramedullary osteosynthesis.
Instruments included in the instrument set give several options for opening and preparation of the intramedullary canal.
The bone tamping mechanism applied in the two-step drill enables a better stabilization while drilling in the femoral neck.
 
Indications:
  • femur shaft fractures;
  • subtrochanteric and intratrochanteric fractures;
  • femur neck fracture;
  • pathological fractures;
  • pseudarthrosis;
  • malunion and non-union treated with other methods.

 

watch the movie here