CHARFIX2 nail FN
is a solution when other treatment method failed.
It is made of titanium and its alloys and is used to join femur and tibia at the side of knee resection or partially removed join surface.
INDICATIONS:
- failed knee arthroplasty;
- post-infaction state;
- periprosthetic fractures;
- post-traumatic state excluding knee prosthesis implantation;
- tumors in knee area;
- loss of or damage to the extensor mechanism;
- oncological changes;
- arthroplasty of the knee joint.
watch the movie here
7,0ChLP HEPI plates
are used to inhibit longitudinal growth of the epiphyseal cartilage in the angular correction of long bones deformation.
Different variants of locking holes spacing in the plates allow for the optimal selection of the implant relatively the deformation cases.
The plates must not be profiled.
7.0ChLP femoral shaft plates
INDICATIONS:
- comminuted fractures of femur shaft;
- malunion or non-union of the bone.
Due to the more favorable force distribution, it is recomeded to use longer plates.
It is not allowed to profile the locking plates in percutaneous method of implantation with the use of targeters. Implant profiling prevents its proper functioning with the targeter.
CHARFIX femoral nail
CHARFIX femoral nail is a universal solution, which depending on a fracture type, enables the intramedullary fixation with the reconstructive, compression, dynamic, static or retrograde method.
Retrograde nail insertion grants the intramedullary osteosynthesis of a femur, in which there already has been a hip prosthesis or other implant inserted in its proximal part.
The locking set – an integral part of the system allows the compression fixation of the condyles.
The combination of three different nails in one implant improves effectiveness of the whole medical team – simplifies mastering of the surgery technique, reduces logistic problems and gives a great flexibility during the surgery.
CHARFIX2 anatomical femoral nail
CHARFIX2 anatomical femoral nail is a next generation nail that is shaped in several planes to better match the femur anatomy. The nail can be inserted through the lateral insertion point.
This makes the implantation easier and results with less trauma to the patient.
The nail enables to fix femur applying static, dynamic, compression or reconstructive intramedullary osteosynthesis.
Instruments included in the instrument set give several options for opening and preparation of the intramedullary canal.
The bone tamping mechanism applied in the two-step drill enables a better stabilization while drilling in the femoral neck.
Indications:
- femur shaft fractures;
- subtrochanteric and intratrochanteric fractures;
- femur neck fracture;
- pathological fractures;
- pseudarthrosis;
- malunion and non-union treated with other methods.